|   | 
Details
   web
Records
Author Roijezon, U.; Djupsjobacka, M.; Bjorklund, M.; Hager-Ross, C.; Grip, H.; Liebermann, D.G.
Title Kinematics of fast cervical rotations in persons with chronic neck pain: a cross-sectional and reliability study Type Journal Article
Year 2010 Publication BMC Musculoskeletal Disorders Abbreviated Journal BMC Musculoskelet Disord
Volume 11 Issue Pages (up) 222
Keywords Adult; Aged; Biomechanics/*physiology; Cervical Vertebrae/*physiopathology; Chronic Disease; Cross-Sectional Studies; Female; Head Movements/*physiology; Humans; Middle Aged; Neck Pain/*diagnosis/*etiology/physiopathology; Physical Examination/methods; Reproducibility of Results; Rotation/*adverse effects; Time Factors; Young Adult
Abstract BACKGROUND: Assessment of sensorimotor function is useful for classification and treatment evaluation of neck pain disorders. Several studies have investigated various aspects of cervical motor functions. Most of these have involved slow or self-paced movements, while few have investigated fast cervical movements. Moreover, the reliability of assessment of fast cervical axial rotation has, to our knowledge, not been evaluated before. METHODS: Cervical kinematics was assessed during fast axial head rotations in 118 women with chronic nonspecific neck pain (NS) and compared to 49 healthy controls (CON). The relationship between cervical kinematics and symptoms, self-rated functioning and fear of movement was evaluated in the NS group. A sub-sample of 16 NS and 16 CON was re-tested after one week to assess the reliability of kinematic variables. Six cervical kinematic variables were calculated: peak speed, range of movement, conjunct movements and three variables related to the shape of the speed profile. RESULTS: Together, peak speed and conjunct movements had a sensitivity of 76% and a specificity of 78% in discriminating between NS and CON, of which the major part could be attributed to peak speed (NS: 226 +/- 88 degrees /s and CON: 348 +/- 92 degrees /s, p < 0.01). Peak speed was slower in NS compared to healthy controls and even slower in NS with comorbidity of low-back pain. Associations were found between reduced peak speed and self-rated difficulties with running, performing head movements, car driving, sleeping and pain. Peak speed showed reasonably high reliability, while the reliability for conjunct movements was poor. CONCLUSIONS: Peak speed of fast cervical axial rotations is reduced in people with chronic neck pain, and even further reduced in subjects with concomitant low back pain. Fast cervical rotation test seems to be a reliable and valid tool for assessment of neck pain disorders on group level, while a rather large between subject variation and overlap between groups calls for caution in the interpretation of individual assessments.
Address Centre for Musculoskeletal Research, University of Gavle, Sweden. ulrik.roijezon@ltu.se
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1471-2474 ISBN Medium
Area Expedition Conference
Notes PMID:20875135 Approved no
Call Number Serial 31
Permanent link to this record
 

 
Author Friedman, Jason; SKM, Varadhan; Zatsiorsky, Vladimir M.; Latash, Mark L.
Title The sources of two components of variance: an example of multifinger cyclic force production tasks at different frequencies Type Journal Article
Year 2009 Publication Experimental Brain Research Abbreviated Journal Exp Brain Res
Volume 196 Issue 2 Pages (up) 263-277
Keywords
Abstract In a multifinger cyclic force production task, the finger force variance measured across trials can be decomposed into two components, one that affects the combined force output (“bad variance”) and one that does not (“good variance”). Previous studies have found similar time patterns of “bad variance” and force rate leading to an approximately linear relationship between them. Based on this finding and a recently developed model of multifinger force production, we expected the “bad variance” during cyclic force production to increase monotonically with the rate of force change, both within a cycle and across trials at different frequencies. Alternatively, “bad variance” could show a dependence on task frequency, not on actual force derivative values. Healthy subjects were required to produce cyclic force patterns to prescribed targets by pressing on unidimensional force sensors, at a frequency set by a metronome. The task was performed with only the index finger, and with all four fingers. In the task with all four fingers, the “good variance” increased approximately linearly with an increase in the force magnitude. The “bad variance” showed within-a-cycle modulation similar to that of the force rate. However, an increase in the frequency did not lead to an increase in the “bad variance” that could be expected based on the natural relationships between action frequency and the rate of force change modulation. The results have been interpreted in the framework of an earlier model of multifinger force production where “bad variance” is a result of variance of the timing parameter. The unexpected lack of modulation of the “bad variance” with frequency suggests a drop in variance of the timing parameter with increased frequency. This mechanism may serve to maintain a constant acceptable level of variance under different conditions.
Address Department of Kinesiology, The Pennsylvania State University, University Park, PA 16802, USA
Corporate Author Thesis
Publisher Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1432-1106 ISBN Medium
Area Expedition Conference
Notes PMID:19468721 Approved no
Call Number Penn State @ write.to.jason @ Serial 15
Permanent link to this record
 

 
Author Raveh, E.; Friedman, J.; Portnoy, S.
Title Visuomotor behaviors and performance in a dual-task paradigm with and without vibrotactile feedback when using a myoelectric controlled hand Type Journal Article
Year 2018 Publication Assistive Technology Abbreviated Journal Assistive Technology
Volume 30 Issue Pages (up) 274-280
Keywords
Abstract
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1040-0435 ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 85
Permanent link to this record
 

 
Author Tenenbaum, G.; Kohler, N.; Shraga, S.; Liebermann, D.G.; Lidor, R.
Title Anticipation and confidence of decisions related to skilled performance Type Journal Article
Year 1996 Publication Journal of Sport Psychology Abbreviated Journal
Volume 27 Issue Pages (up) 293-307
Keywords
Abstract This study was carried out to examine anticipatory decisions of novice, intermediate, and expert tennis players and the confidence with which these decisions are made by these athletes. Perceived eye-focus was also measured to verify whether it is related to expertise level prior to action execution. Forty-five Australian players, 15 in each skill category, were exposed to 6 temporal occluded film conditions (480, 320, 160 ms prior to racquet-ball contact, at contact, and 160 and 320 ms after contact) in randomized order within 8 tennis strokes. In each condition, after viewing the filmed sequence, they were asked to report the final ball location of the opponent's stroke, how confident they were in this decision, and their perceived eye-focus location during the sequence. Experts and intermediates were superior in anticipatory decisions to their counterparts, only under short exposure durations. Novices showed more confidence than experts and intermediates at the beginning of the sequence, but after 160 and 320 ms of ball-racquet contact, experts were much more confident than novices, and intermediates. Self-reported eye-focus differed substantially with respect to expertise level. While experts attended to several locations prior to ball-racquet contact, intermediate and novice players gazed at one location. After contact, the reverse was evident. The findings are in partial agreement with other studies which have applied the temporal occlusion paradigm to study expert-novice differences in anticipatory skills.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 59
Permanent link to this record
 

 
Author Goodman, D.; Liebermann, D.G.
Title Time-to-contact as a determiner of action: vision and motor control Type Book Chapter
Year 1992 Publication Vision and Motor Control Abbreviated Journal
Volume Issue Pages (up) 335-349
Keywords
Abstract
Address
Corporate Author Thesis
Publisher Elsevier Pub. Co Place of Publication Amsterdam, Holland Editor D. Elliott; J. Proteau
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes Approved no
Call Number Serial 43
Permanent link to this record