toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Prushansky, T.; Kaplan-Gadasi, L.; Friedman, J. pdf  url
doi  openurl
  Title The relationship between thoracic posture and ultrasound echo intensity of muscles spanning this region in healthy men and women Type Journal Article
  Year 2023 Publication Physiotherapy Theory and Practice Abbreviated Journal Physiother Theory Pract  
  Volume 39 Issue 6 Pages 1257-1265  
  Keywords Ultrasound imaging; muscle echogenicity; posture; thoracic kyphosis  
  Abstract PURPOSE: Skeletal muscle echogenicity intensity (EI) is considered a measure of muscle quality, being associated with old age and pathologies. Whether EI variations can be identified in healthy adults, due to habitual shortened or elongated muscle position is unknown. Thus, this study aimed to assess the relationship between thoracic kyphosis angulation and EI scores of muscles spanning this region ((Lower Trapezius (LT), Rhomboid Major (RM), Erector Spine (ES)) in healthy young people and in addition to examine the relationship between the change in thoracic kyphosis angle from relaxed to upright position (â�� degrees ) and the EI of these muscles. METHODS: Thoracic kyphosis in relaxed and erect standing was measured using a digital inclinometer in 29 healthy adults (16 women, 13 men), aged 25-35 years. The thoracic kyphosis angles including the difference between relaxed and erect postures (â�� degrees ) were correlated to the EI scores of right and left LT, RM and ES. RESULTS: No significant differences in EI were found between the 3 muscles EI or between sides, hence they were pooled together to a total thoracic EI score (TTEI). Although the TTEI did not correlate with relaxed or erect thoracic kyphosis, it was significantly but negatively correlated with â�� degrees in the entire group: Pearson's correlation coefficient of r = -0.544; p = .01 and in men; r = -0.732; p = .01, failing to reach significance in women; r = -0.457. CONCLUSION: The negative association between the EI of the explored muscles and â�� degrees could imply a possible relationship between these muscles range of movement excursions and their composition.  
  Address (down) Department of Physical Therapy, the Stanley Stayer School of Health Professions, Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0959-3985 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:35125048 Approved no  
  Call Number Serial 116  
Permanent link to this record
 

 
Author Liebermann, D.G.; Biess, A.; Friedman, J.; Gielen, C.C.A.M.; Flash, T. pdf  url
doi  openurl
  Title Intrinsic joint kinematic planning. I: reassessing the Listing's law constraint in the control of three-dimensional arm movements Type Journal Article
  Year 2006 Publication Experimental Brain Research Abbreviated Journal Exp Brain Res  
  Volume 171 Issue 2 Pages 139-154  
  Keywords Adolescent; Adult; Analysis of Variance; *Arm; Biomechanics; Eye Movements/*physiology; Humans; Joints/*physiology; Male; Movement/*physiology; *Musculoskeletal System; Orientation/*physiology; Posture  
  Abstract This study tested the validity of the assumption that intrinsic kinematic constraints, such as Listing's law, can account for the geometric features of three-dimensional arm movements. In principle, if the arm joints follow a Listing's constraint, the hand paths may be predicted. Four individuals performed 'extended arm', 'radial', 'frontal plane', and 'random mixed' movements to visual targets to test Listing's law assumption. Three-dimensional rotation vectors of the upper arm and forearm were calculated from three-dimensional marker data. Data fitting techniques were used to test Donders' and Listing's laws. The coefficient values obtained from fitting rotation vectors to the surfaces described by a second-order equation were analyzed. The results showed that the coefficients that represent curvature and twist of the surfaces were often not significantly different from zero, particularly not during randomly mixed and extended arm movements. These coefficients for forearm rotations were larger compared to those for the upper arm segment rotations. The mean thickness of the rotation surfaces ranged between approximately 1.7 degrees and 4.7 degrees for the rotation vectors of the upper arm segment and approximately 2.6 degrees and 7.5 degrees for those of the forearm. During frontal plane movements, forearm rotations showed large twist scores while upper arm segment rotations showed large curvatures, although the thickness of the surfaces remained low. The curvatures, but not the thicknesses of the surfaces, were larger for large versus small amplitude radial movements. In conclusion, when examining the surfaces obtained for the different movement types, the rotation vectors may lie within manifolds that are anywhere between curved or twisted manifolds. However, a two-dimensional thick surface may roughly represent a global arm constraint. Our findings suggest that Listing's law is implemented for some types of arm movement, such as pointing to targets with the extended arm and during radial reaching movements.  
  Address (down) Department of Physical Therapy, Sackler Faculty of Medicine, Tel-Aviv University, 69978, Ramat Aviv, Israel. dlieberm@post.tau.ac.il  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0014-4819 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:16341526 Approved no  
  Call Number Penn State @ write.to.jason @ Serial 18  
Permanent link to this record
 

 
Author Krasovsky, T.; Weiss, P.L.; Zuckerman, O.; Bar, A.; Keren-Capelovitch, T.; Friedman, J. pdf  url
doi  openurl
  Title DataSpoon: Validation of an Instrumented Spoon for Assessment of Self-Feeding Type Journal Article
  Year 2020 Publication Sensors (Basel, Switzerland) Abbreviated Journal Sensors (Basel)  
  Volume 20 Issue 7 Pages  
  Keywords concurrent validity; feasibility; kinematics; outcome assessment; rehabilitation  
  Abstract Clinically feasible assessment of self-feeding is important for adults and children with motor impairments such as stroke or cerebral palsy. However, no validated assessment tool for self-feeding kinematics exists. This work presents an initial validation of an instrumented spoon (DataSpoon) developed as an evaluation tool for self-feeding kinematics. Ten young, healthy adults (three male; age 27.2 +/- 6.6 years) used DataSpoon at three movement speeds (slow, comfortable, fast) and with three different grips: “natural”, power and rotated power grip. Movement kinematics were recorded concurrently using DataSpoon and a magnetic motion capture system (trakSTAR). Eating events were automatically identified for both systems and kinematic measures were extracted from yaw, pitch and roll (YPR) data as well as from acceleration and tangential velocity profiles. Two-way, mixed model Intraclass correlation coefficients (ICC) and 95% limits of agreement (LOA) were computed to determine agreement between the systems for each kinematic variable. Most variables demonstrated fair to excellent agreement. Agreement for measures of duration, pitch and roll exceeded 0.8 (excellent agreement) for >80% of speed and grip conditions, whereas lower agreement (ICC < 0.46) was measured for tangential velocity and acceleration. A bias of 0.01-0.07 s (95% LOA [-0.54, 0.53] to [-0.63, 0.48]) was calculated for measures of duration. DataSpoon enables automatic detection of self-feeding using simple, affordable movement sensors. Using movement kinematics, variables associated with self-feeding can be identified and aid clinical reasoning for adults and children with motor impairments.  
  Address (down) Department of Physical Therapy, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1424-8220 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:32283624; PMCID:PMC7180859 Approved no  
  Call Number Serial 104  
Permanent link to this record
 

 
Author Friedman, Jason; SKM, Varadhan; Zatsiorsky, Vladimir M.; Latash, Mark L. pdf  url
doi  openurl
  Title The sources of two components of variance: an example of multifinger cyclic force production tasks at different frequencies Type Journal Article
  Year 2009 Publication Experimental Brain Research Abbreviated Journal Exp Brain Res  
  Volume 196 Issue 2 Pages 263-277  
  Keywords  
  Abstract In a multifinger cyclic force production task, the finger force variance measured across trials can be decomposed into two components, one that affects the combined force output (“bad variance”) and one that does not (“good variance”). Previous studies have found similar time patterns of “bad variance” and force rate leading to an approximately linear relationship between them. Based on this finding and a recently developed model of multifinger force production, we expected the “bad variance” during cyclic force production to increase monotonically with the rate of force change, both within a cycle and across trials at different frequencies. Alternatively, “bad variance” could show a dependence on task frequency, not on actual force derivative values. Healthy subjects were required to produce cyclic force patterns to prescribed targets by pressing on unidimensional force sensors, at a frequency set by a metronome. The task was performed with only the index finger, and with all four fingers. In the task with all four fingers, the “good variance” increased approximately linearly with an increase in the force magnitude. The “bad variance” showed within-a-cycle modulation similar to that of the force rate. However, an increase in the frequency did not lead to an increase in the “bad variance” that could be expected based on the natural relationships between action frequency and the rate of force change modulation. The results have been interpreted in the framework of an earlier model of multifinger force production where “bad variance” is a result of variance of the timing parameter. The unexpected lack of modulation of the “bad variance” with frequency suggests a drop in variance of the timing parameter with increased frequency. This mechanism may serve to maintain a constant acceptable level of variance under different conditions.  
  Address (down) Department of Kinesiology, The Pennsylvania State University, University Park, PA 16802, USA  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1432-1106 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:19468721 Approved no  
  Call Number Penn State @ write.to.jason @ Serial 15  
Permanent link to this record
 

 
Author Friedman, Jason; Latash, Mark L.; Zatsiorsky, Vladimir M. pdf  url
doi  openurl
  Title Prehension synergies: a study of digit force adjustments to the continuously varied load force exerted on a partially constrained hand-held object Type Journal Article
  Year 2009 Publication Experimental Brain Research Abbreviated Journal Exp Brain Res  
  Volume 197 Issue 1 Pages 1-13  
  Keywords  
  Abstract We examined how the digit forces adjust when a load force acting on a hand-held object continuously varies. The subjects were required to hold the handle still while a linearly increasing and then decreasing force was applied to the handle. The handle was constrained, such that it could only move up and down, and rotate about a horizontal axis. In addition, the moment arm of the thumb tangential force was 1.5 times the moment arm of the virtual finger (VF, an imagined finger with the mechanical action equal to that of the four fingers) force. Unlike the situation when there are equal moment arms, the experimental setup forced the subjects to choose between (a) sharing equally the increase in load force between the thumb and VF but generating a moment of tangential force, which had to be compensated by negatively co-varying the moment due to normal forces, or (b) sharing unequally the load force increase between the thumb and VF but preventing generation of a moment of tangential forces. We found that different subjects tended to use one of these two strategies. These findings suggest that the selection by the CNS of prehension synergies at the VF-thumb level with respect to the moment of force is non-obligatory and reflects individual subject preferences. This unequal sharing of the load by the tangential forces, in contrast to the previously observed equal sharing, suggests that the invariant feature of prehension may be a correlated increase in tangential forces rather than an equal increase.  
  Address (down) Department of Kinesiology, The Pennsylvania State University, 39 Recreation Building, University Park, PA, 16802, USA, jason.friedman@psu.edu  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1432-1106 ISBN Medium  
  Area Expedition Conference  
  Notes PMID:19554319 Approved no  
  Call Number Penn State @ write.to.jason @ Serial 16  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: